X-CHECK 310 MF is an X-Ray inspection desk for Multi-Layer panels, before and after the drilling process. The inspection of overlapped targets before drilling is to avoid to drill panels with high misalignment between the internal layers. After drilling, the use of X-Check 310 MF allows to evaluate the centering errors between holes and the relative pad. X-CHECK 310 MF is an evolution of previous model 300.
It is built with a fully shielded robust structure, which contains and holds:
A dedicated software application shows, with a simple click the X-Ray control Panel, which permits to adjust the KV, to display the actual KV and mA values, to display alarms, which are connected to risky conditions for the operator and the equipments.
The X-ray control panel can be hidden with another simple click when necessary, in order to grant the functionalities connected to the inspection job.
In order to maximise the X-ray tube life and efficiency, the control software sets automatically the anode current (mA) depending on the KV setting and the tube mA/KV characteristic. To the same aim, the software starts automatically the proper warm-up cycle, when required by the inactivity time of the X-ray source.
By pressing the foot switch, the X-rays are turned ON, and within 2 sec the image appears. This is enough for a simple visual evaluation.
Anyway, the camera controller and the X-Check software offer a number of functions for image elaboration in difficult cases. In particular, frame Integration and CCD time integration are very powerful. When the image is "frozen", the Measure menu permits to check the hole to pad centring errors (Fig. 2) or straight lines to measure distances.
Then the image can be stored on the H.D. or printed out with or without the measurements in overlay. Quad image printing (four corners) is also available.
The operator and the environment are protected against X-radiation leakage by means of flexible lead-rubber curtains all around to the camera housing and the exposure room.
These offer full protection against X-Ray emission through the frontal, rear and side openings. The flexible curtains must be changed periodically, and to this aim, they can be easily accessed by removing the upper plate, which holds the cylindrical camera housing.
In addition, a dedicated circuitry inhibits the X-ray emission when the circuit of the signalling lamp is interrupted (lamp filament burnt), according to the existing laws Because of X-Ray presence, the equipment is supplied with a Radio Protection Certificate. This is released by a QUALIFYED EXPERT and it lists the radiation leakage measurements made on the specific equipment, according to EURATOM directives 80/836, 84/466, 84/467, 89/618, 90/641, 92/3, which concern ionising radiations.
Since the X-Ray leakage is less than 1 µSv/h at any point of the machine envelope, the operator is considered not exposed person. This means that because of the efficiency of the shielding system, there is no need of wearing the exposure badge for periodical check. The customer must simply declare the detention of an X-Ray equipment to the local Safety Department according to the local laws. All the components are CE compliant.
INSPECTING DETAIILS |
OPTION |
Inspection: Full panel area | Photographic printer |
Panel input openings: 24mm high |
All information subjected to change without notice!
For more information, visit the website or send us your information request.
Typically the reference holes are used to inset pins, which will be used to clamp the panel with the accurate alignment to the X, Y axes of the drilling machine. To this aim, the reference holes must be executed with best optimization respect to the inner lay-up of the multi-layer panel. The process to drill reference holes is made in two steps: 1) In the first step the machine will detect the centers of those targets that have been chosen to represent the internal lay-up. The enlargement/shrinking, due to the previous pressing process, as well as the registration errors are considered. 2) In the second step the programmed holes will be executed in optimized positions based on the detected topography, but at a definite reciprocal distance, as required for pins. The drilling is performed by a pneumatic spindle using a standard drilling tool with ring. The rotation speed is fixed at 30.000 rpm. The panel is clamped by vacuum area at the center of table. The table is made by a material that is X-Ray transparent and offers the possibility of inspecting any kind of panels or PCB's in any point, including the vacuum area, which is also X-ray transparent. The software offers a very friendly and self-explaining interface toward the operator.
All information subjected to change without notice!
For more information, visit the website or send us your information request.
At Adeon we believe that it is the quality of our work that placed us in our current position, and quality is what we try to improve with everything we do. European PCB manufacturers are often challenged to produce many different designs and technology levels every day. This makes it challenging to select and provide equipment that is capable of doing that. Our goal is to offer the best service and support against affordable rates to the highest standards to help our customers to stay at the forefront of technological developments.
Weidehek 26
Industrial Area Haagse Beemden # 4530
NL-4824 AS Breda
The Netherlands
Telephone: +31 (0)76 541 00 08
Fax: +31 (0)76 542 50 59
E-mail: info@adeon.nl